Lamotte ColorQ Professional 7 reagents are your gateway to specific water high quality evaluation. Unlock the secrets and techniques hidden inside water samples with ease and accuracy, utilizing these versatile reagents. This information delves into the specifics of those reagents, exploring their software, properties, and important dealing with methods.
From understanding the basic rules of colorimetric evaluation to mastering the exact software procedures, this useful resource supplies an entire toolkit for profitable water high quality testing. Learn to interpret outcomes, troubleshoot widespread points, and guarantee correct measurements with the assistance of skilled insights. Uncover the potential of colorimetric evaluation in numerous fields, together with environmental monitoring, industrial purposes, and educational analysis.
The detailed explanations, sensible examples, and security pointers will equip you with the information and confidence to deal with these reagents successfully.
Introduction to Lamotte ColorQ Professional 7 Reagents
The Lamotte ColorQ Professional 7 reagents are a game-changer in water high quality evaluation. These precision-engineered options permit for fast and correct willpower of assorted parameters, from easy pH measurements to extra advanced analyses like nitrates or phosphates. Their user-friendly design makes them supreme for each skilled labs and enthusiastic residence hobbyists alike.Colorimetric evaluation, the cornerstone of those reagents, depends on the attractive and predictable method that substances change coloration when reacting with particular chemical substances.
This coloration change, usually dramatic and simply noticed, corresponds to a measurable focus of the substance being analyzed. The Lamotte ColorQ Professional 7 system takes this precept and packages it right into a easy, highly effective, and correct instrument.
Function and Supposed Functions
The Lamotte ColorQ Professional 7 reagents are particularly designed for a big selection of water high quality assessments. They supply fast and dependable outcomes for parameters like pH, alkalinity, hardness, ammonia, and numerous nutrient ranges. This makes them helpful in monitoring water sources for public well being and security, making certain compliance with laws, and even in hobbyist aquariums.
Varieties of Reagents
The Lamotte ColorQ Professional 7 system gives a various vary of reagents, meticulously formulated for particular analyses. This consists of reagents for figuring out the focus of assorted ions and compounds in water samples. Every reagent is tailor-made to a particular chemical compound or parameter, making certain correct and dependable outcomes. Examples embody pH reagents, alkalinity reagents, and nutrient reagents.
Composition of Reagents
The exact composition of every reagent is rigorously guarded and optimized for its meant objective. The reagents usually comprise particular chromogenic indicators and stabilizing brokers. These parts react with the goal analyte within the water pattern to provide a coloration change, permitting for the quantification of the analyte. The detailed composition is important for making certain accuracy and reliability within the outcomes.
Dealing with and Storage of Reagents
Correct dealing with and storage of the reagents are essential for sustaining their effectiveness and security. Reagents needs to be saved of their unique containers, tightly sealed and away from direct daylight and excessive temperatures. Keep away from contamination through the use of clear and applicable instruments for transferring and shelling out the reagents. All the time seek the advice of the producer’s directions for particular pointers on dealing with and storage procedures.
Security Precautions
All the time put on applicable private protecting gear (PPE) when dealing with the reagents. Seek the advice of the Materials Security Information Sheets (MSDS) for detailed info on the hazards of every reagent. Correct disposal procedures should be adopted to guard the setting. Take additional care to keep away from spills and guarantee correct air flow when working with these reagents.
Reagent Properties and Traits
These Lamotte ColorQ Professional 7 reagents are meticulously crafted for dependable colorimetric evaluation. Understanding their properties, from stability to paint adjustments, is essential to correct outcomes. This part delves into the specifics of those reagents, making certain you are geared up to confidently make the most of them in your water high quality testing.These reagents are designed to be extremely steady, minimizing the danger of degradation over time.
Correct storage situations, as Artikeld within the product handbook, are essential to sustaining their integrity and accuracy. This stability permits for constant outcomes, even when testing over prolonged intervals.
Reagent Stability and Shelf Life
The steadiness of the reagents is paramount for dependable evaluation. Correct storage, away from direct daylight and excessive temperatures, is essential. The producer’s advisable storage situations needs to be meticulously adopted. Usually, these reagents keep their efficacy for a particular interval, normally famous on the product label. For instance, a typical shelf life for ColorQ Professional 7 reagents is 12-18 months when saved accurately.
Past this, efficiency may degrade barely, impacting the accuracy of your measurements.
Colour Change Correlation with Analyte Focus
The reagents’ exceptional potential to alter coloration in response to various analyte concentrations is a cornerstone of colorimetric evaluation. This coloration change is straight proportional to the quantity of the precise substance being measured. A standardized coloration chart, supplied with the reagents, aids in visually correlating the noticed coloration with the corresponding focus values. For example, a progressively deepening shade of blue within the reagent answer may point out a rising focus of ammonia.
Components Affecting Measurement Accuracy and Precision
A number of elements can affect the accuracy and precision of colorimetric measurements. Variations in temperature, improper pattern preparation, and reagent contamination are a number of essential parts that may negatively have an effect on your outcomes. Utilizing a calibrated spectrophotometer can reduce these results. It is essential to keep up correct temperature management and make sure the purity of reagents to acquire probably the most correct readings.
One other issue to think about is the consistency of the sunshine supply used to check the colour of the answer with the colour chart.
Efficiency Comparability of Completely different Reagent Units
Completely different reagent units could range when it comes to sensitivity, selectivity, and pace of coloration growth. The producer’s specs present particulars on the efficiency traits of every set. Some units could be extra delicate to particular analytes, making them appropriate for decrease focus measurements. This info is essential for choosing the suitable reagent set on your particular software and wishes.
For example, one set could be higher at detecting nitrates, whereas one other is optimized for phosphates.
Security Precautions for Dealing with Reagents
Protected dealing with of reagents is of utmost significance. All the time put on applicable private protecting gear (PPE), together with gloves and security glasses. Comply with the producer’s directions concerning dealing with, storage, and disposal. Some reagents could be corrosive or hazardous; at all times prioritize security. Correct air flow and applicable waste disposal procedures needs to be adopted to reduce potential dangers.
Moreover, any spills needs to be instantly cleaned up following established procedures.
Utility Procedures and Strategies
Unlocking the secrets and techniques of water high quality, and different purposes, is simpler than you suppose with the Lamotte ColorQ Professional 7 reagents. These reagents, meticulously crafted, are your gateway to specific colorimetric analyses. Mastering the appliance procedures will empower you to make knowledgeable selections, whether or not you are a seasoned environmental scientist or a curious scholar.Colorimetric evaluation, leveraging the facility of coloration adjustments, gives an easy and accessible technique for figuring out numerous chemical parts in a pattern.
These easy but efficient methods, mixed with the accuracy of the Lamotte ColorQ Professional 7, present dependable outcomes. This part will information you thru the usual procedures and sensible purposes.
Commonplace Procedures for Colorimetric Analyses
This part particulars the important steps for conducting correct and dependable colorimetric analyses utilizing the Lamotte ColorQ Professional 7 reagents. Exact measurement and adherence to the protocols are key to acquiring correct outcomes.The method sometimes entails getting ready a pattern, including the suitable reagent, and permitting the combination to react. The ensuing coloration change is then in comparison with a coloration chart or a digital instrument for quantification.
Sustaining a managed setting and utilizing standardized procedures are essential to reduce errors and maximize the reliability of the outcomes.
Step-by-Step Information for Conducting Analyses, Lamotte colorq professional 7 reagents
A scientific strategy ensures dependable outcomes. Comply with these steps to conduct colorimetric analyses successfully:
- Pattern Preparation: Precisely accumulate and put together the pattern in response to the precise directions supplied with the reagents. This may occasionally contain filtration, dilution, or different essential steps.
- Reagent Addition: Fastidiously add the suitable Lamotte ColorQ Professional 7 reagent to the ready pattern. All the time observe the desired reagent ratios. The addition needs to be exact to realize the specified coloration change.
- Response Time: Permit the combination to react for the prescribed length, usually a couple of minutes, as specified within the reagent directions. This enables the chemical response to completely develop and make sure the coloration is steady.
- Colour Comparability: Fastidiously evaluate the ensuing coloration of the pattern combination to the colour requirements supplied with the reagents. Visible matching or use of a colorimeter helps decide the focus.
- Outcome Interpretation: Seek the advice of the reagent directions or a corresponding reference chart to find out the focus of the goal analyte based mostly on the noticed coloration match.
Functions in Water High quality Testing
The Lamotte ColorQ Professional 7 reagents excel in numerous water high quality testing purposes. Their versatility makes them a worthwhile instrument for assessing water high quality parameters.
- pH Willpower: The reagents are essential for figuring out the acidity or alkalinity of water samples, important for assessing the general well being of aquatic ecosystems. Variations in pH can point out air pollution or different environmental elements.
- Dissolved Oxygen Evaluation: Dissolved oxygen ranges are important for aquatic life. The reagents permit for fast and correct measurement of dissolved oxygen, enabling assessments of water high quality and its affect on aquatic life.
- Turbidity Measurement: Turbidity, the cloudiness of water, is a vital indicator of water high quality. The reagents present a technique for measuring turbidity, figuring out potential contamination sources.
Water High quality Take a look at Process
This desk Artikels a typical water high quality take a look at process utilizing the Lamotte ColorQ Professional 7 reagents for dissolved oxygen evaluation.
Step | Process |
---|---|
1 | Gather a water pattern. |
2 | Put together the pattern in response to directions. |
3 | Add the desired reagent to the pattern. |
4 | Permit the combination to react for five minutes. |
5 | Evaluate the colour of the ensuing answer to the colour chart. |
6 | Decide the dissolved oxygen stage from the colour chart. |
Reagents for Completely different Water High quality Parameters
This desk lists the reagents wanted for numerous water high quality parameters.
Parameter | Reagent(s) |
---|---|
pH | Particular pH reagents |
Dissolved Oxygen | Dissolved oxygen reagents |
Turbidity | Turbidity reagents |
Nitrate | Nitrate reagents |
Troubleshooting and Frequent Points
Navigating the world of water high quality evaluation can generally really feel like a treasure hunt, however with a little bit know-how, you may uncover hidden clues and obtain correct outcomes. Understanding potential pitfalls and the right way to overcome them is essential to dependable evaluation. This part delves into widespread issues and their options, making certain you may confidently interpret your outcomes.
Faint or Inconsistent Colour Growth
Colour growth is the guts of the ColorQ Professional 7 technique. Variations can stem from a number of elements. Improper reagent preparation, insufficient mixing, or temperature fluctuations can all affect the depth and consistency of the colour. This part supplies troubleshooting steps to make sure dependable coloration growth.
- Confirm reagent preparation: Guarantee reagents are ready in response to the producer’s directions. A slight deviation within the mixing ratio or timing can result in delicate however vital coloration variations. Double-check the precise directions for the reagent in use.
- Guarantee thorough mixing: Correct mixing is essential. Vigorous shaking or swirling ensures all parts are properly mixed, maximizing coloration growth. Use a devoted mixing instrument for optimum outcomes, making certain thorough mixing.
- Management temperature: Temperature fluctuations can affect the speed of coloration growth. Retailer reagents and keep the evaluation setting on the advisable temperature. A relentless temperature setting will reduce the impact of temperature on coloration growth.
Incorrect or Inaccurate Outcomes
Exact measurements are paramount in water high quality evaluation. Discrepancies could be traced to a wide range of elements, from human error to environmental situations. This part supplies insights into minimizing error and attaining dependable outcomes.
- Confirm instrument calibration: Make sure the ColorQ Professional 7 instrument is calibrated often in response to the producer’s pointers. Calibration checks assure the accuracy of the instrument’s readings, which is key to correct outcomes.
- Standardize pattern preparation: Consistency in pattern preparation is important. This consists of applicable pattern assortment methods and correct dilution protocols. Adhering to established procedures is essential to dependable outcomes.
- Correct instrument use: Comply with the precise directions for utilizing the ColorQ Professional 7 instrument. Incorrect instrument operation can result in inaccurate readings. Familiarity with the instrument and its options is essential to acquiring dependable outcomes.
- Assessment of reagents and storage: Study reagents and their storage situations. Improper storage or expiration dates can result in inaccurate outcomes. Comply with the producer’s pointers for storing and dealing with reagents to make sure accuracy.
Troubleshooting Particular Points
Troubleshooting particular points can usually be resolved by checking the previous factors. Nevertheless, sure points could require additional investigation. This part presents a sensible strategy to tackling distinctive issues.
- Colour readings are inconsistent: Assessment reagent preparation, guarantee correct mixing, and management temperature fluctuations. Confirm instrument calibration and pattern preparation consistency.
- Outcomes are considerably completely different from anticipated values: Confirm instrument calibration, overview pattern preparation methods, and guarantee applicable reagents are used. Evaluate your outcomes to a identified commonplace or management pattern for added validation.
Reagent Compatibility and Interactions

Understanding how the Lamotte ColorQ Professional 7 reagents work together with completely different pattern varieties is essential for correct and dependable outcomes. Reagent compatibility ensures that the meant chemical reactions proceed as anticipated, minimizing interference and maximizing the precision of your evaluation. This part explores the nuances of reagent compatibility, potential interactions, and the affect of environmental elements on the colorimetric course of.
Reagent Compatibility with Pattern Varieties
The success of any colorimetric evaluation hinges on the compatibility of the reagents with the pattern matrix. Completely different pattern varieties can comprise numerous substances which may intervene with the meant response. That is the place meticulous consideration to element is paramount. For example, extremely coloured samples may masks the colour change related to the specified response. Conversely, sure pattern parts may react with the reagents in sudden methods, resulting in false positives or negatives.
- Water samples usually comprise dissolved minerals and natural matter. The presence of those parts can affect the response between the reagents and the goal analyte. Cautious pre-treatment of the water pattern is commonly essential to make sure optimum compatibility and reduce interference.
- Soil samples can comprise a fancy combination of natural and inorganic compounds. These compounds can have an effect on the colorimetric response and may require particular pattern preparation procedures to take away interferences.
- Wastewater samples steadily comprise a variety of pollution and contaminants. The presence of those substances can affect the response, demanding particular consideration in reagent choice and pattern preparation to acquire correct outcomes.
Potential Reagent Interactions with Pattern Elements
Figuring out potential interactions between reagents and pattern parts is essential for correct evaluation. Interferences can come up from numerous pattern parts, equivalent to interfering ions or complexing brokers. These interactions can considerably affect the accuracy of the outcomes.
- Interfering ions: Sure ions within the pattern can react with the reagents, resulting in false outcomes. For instance, excessive concentrations of chloride ions in a water pattern may intervene with the colour growth in a particular evaluation. Acceptable pattern preparation methods, equivalent to ion trade or filtration, can usually mitigate these points.
- Complexing brokers: Complexing brokers within the pattern can bind to the reagents, hindering their interplay with the goal analyte. This may end up in a lowered coloration change or an inaccurate quantification of the goal part.
Impact of pH and Temperature on Colorimetric Response
The pH and temperature of the pattern can considerably affect the colorimetric response. The optimum pH vary for a selected response is commonly essential. Sustaining the right temperature is equally essential.
- pH affect: A change in pH can alter the ionization state of the reagents or the analyte, impacting the response fee and the colour depth. The colorimetric response may proceed in a different way at numerous pH values, resulting in completely different outcomes. Understanding the best pH vary for the precise evaluation is important.
- Temperature affect: Temperature fluctuations can have an effect on the response fee. The colorimetric response could be sooner or slower at completely different temperatures, impacting the time required for the colour to develop. Sustaining a steady temperature throughout the evaluation is essential for correct outcomes.
Evaluating Reagent Compatibility Throughout Pattern Matrices
The compatibility of reagents varies considerably throughout completely different pattern matrices. Understanding these variations is essential for choosing the suitable reagents and making certain correct outcomes.
- Completely different pattern matrices: Completely different pattern matrices, equivalent to water, soil, or wastewater, can current distinctive challenges. Every matrix may comprise numerous interfering parts that may have an effect on the colorimetric response in a different way. A complete understanding of the pattern matrix is important to decide on the proper reagents and applicable pattern preparation strategies.
Reagent Compatibility Abstract Desk
Pattern Sort | Potential Interferences | Mitigation Methods |
---|---|---|
Water | Dissolved minerals, natural matter | Pre-treatment, filtration |
Soil | Natural and inorganic compounds | Extraction, digestion |
Wastewater | Pollution, contaminants | Dilution, pre-treatment |
Calibration and Validation Procedures

Unlocking the true potential of your Lamotte ColorQ Professional 7 requires a eager eye for element and a dedication to precision. Calibration and validation aren’t simply steps in a protocol; they’re cornerstones of dependable outcomes. Correct measurements are the muse of any profitable water high quality evaluation, and these procedures guarantee your instrument and reagents persistently ship reliable readings.Calibration ensures your instrument’s readings precisely mirror the precise concentrations of gear within the water samples.
Validation goes a step additional, confirming that your entire course of – from reagent preparation to instrument operation – produces reliable knowledge. This meticulous strategy ensures you are not simply measuring, however understanding the standard of your water sources.
Significance of Calibration
Correct measurements are paramount in water high quality evaluation. Calibration establishes a direct relationship between the instrument’s output and the identified focus of an ordinary. With out correct calibration, outcomes could be considerably skewed, resulting in misinterpretations and doubtlessly expensive errors. Calibration ensures that the instrument persistently responds to identified concentrations in a predictable method, enabling dependable and repeatable measurements.
Calibration Steps for Lamotte ColorQ Professional 7
Correct calibration entails a collection of well-defined steps, making certain the instrument persistently delivers exact readings.
- Put together the calibration requirements as per the producer’s directions. This meticulous step is essential for acquiring correct outcomes.
- Introduce the calibration requirements into the instrument’s pattern chamber. Guarantee correct placement and keep away from any contamination.
- Permit the instrument to stabilize in response to the producer’s specs. Stability is essential to acquiring constant readings.
- File the instrument’s readings for every commonplace. These readings shall be used for calibration calculations.
- Use the instrument’s software program to carry out the calibration calculation. This software program sometimes handles the advanced mathematical relationships between the requirements and the instrument readings.
Calibration Requirements and Procedures
A well-structured calibration course of makes use of a set of identified focus requirements. A typical calibration process makes use of a number of requirements spanning a variety of concentrations, permitting for a complete calibration curve.
Commonplace Focus (mg/L) | Process |
---|---|
10 | Dissolve a exactly measured quantity of ordinary substance in a identified quantity of solvent. |
20 | Repeat the process for every commonplace, making certain consistency in measurement and mixing. |
30 | Precisely measure the ready options, then introduce them into the instrument. |
40 | Comply with the instrument’s particular calibration protocols. |
50 | File the instrument readings corresponding to every commonplace. |
Validation Strategies
Validating outcomes ensures the reliability of your entire course of. Strategies embody checking for instrument drift, verifying the calibration curve, and testing with identified samples of various concentrations.
- Instrument drift is a standard concern. Common checks with identified requirements assist to detect and proper any adjustments within the instrument’s efficiency over time.
- The calibration curve’s validity should be constantly monitored. If the curve deviates considerably from anticipated values, the calibration course of needs to be repeated.
- Take a look at the instrument’s efficiency with identified samples of various concentrations. Evaluate the outcomes to identified values to evaluate accuracy.
Examples of Reagent Validation
Validation of your entire course of is essential. Testing completely different batches of reagents towards identified samples ensures consistency and reliability. Utilizing identified water samples with identified concentrations, and evaluating the outcomes to anticipated values is a powerful indicator of reagent high quality.
Information Interpretation and Reporting
Unlocking the secrets and techniques hidden inside the vibrant hues of your colorimetric outcomes is a journey of discovery. This part will information you thru deciphering the visible language of coloration and translating it into significant knowledge. From deciphering coloration depth to reporting outcomes, we’ll equip you with the information to confidently talk your findings.
Decoding Colorimetric Outcomes
Visible interpretation is the cornerstone of colorimetric evaluation. Completely different shades of coloration correspond to completely different concentrations of the analyte. A deeper coloration normally signifies a better focus, whereas a lighter coloration signifies a decrease focus. Follow and expertise will improve your potential to shortly and precisely affiliate coloration with focus.
Calculating Analyte Focus
Quantitative evaluation requires a calibration curve, a graph plotting coloration depth towards identified analyte concentrations. This curve acts as a roadmap, permitting you to estimate the focus of an unknown pattern based mostly on its corresponding coloration depth. The calibration curve is usually generated utilizing a set of identified requirements. Utilizing the curve, you may decide the focus from the colour depth.
For example, if a pattern displays a coloration matching the usual with a focus of 10 ppm, the pattern is prone to comprise 10 ppm of the analyte.
Commonplace Codecs for Reporting Outcomes
Uniformity in reporting is essential for knowledge comparability and evaluation. Embrace important particulars just like the date of study, pattern ID, technique used, and the models of focus. Exact and concise reporting permits for straightforward interpretation and avoids ambiguity. A transparent and structured report enhances communication. For instance, a well-formatted report ought to embody a title, summary, supplies and strategies, outcomes, and dialogue sections.
Colour Requirements and Corresponding Concentrations
The next desk illustrates the connection between coloration requirements and corresponding analyte concentrations. These requirements are essential for establishing a calibration curve and deciphering the colour depth of unknown samples.
Colour Commonplace | Analyte Focus (ppm) |
---|---|
Gentle Yellow | 5 |
Medium Yellow | 10 |
Darkish Yellow | 15 |
Orange | 20 |
Crimson | 25 |
Graphical and Tabular Information Illustration
Visualizing knowledge utilizing graphs and tables enhances comprehension and facilitates the identification of developments. A calibration curve, for instance, clearly exhibits the connection between coloration depth and analyte focus. A desk presenting the outcomes of a number of samples permits for straightforward comparability and summarization. A well-designed desk ought to embody clear headings, models, and applicable formatting. For instance, a graph displaying the connection between temperature and coloration depth could be extraordinarily helpful for understanding the dynamics of the method.
Security Precautions and Dealing with: Lamotte Colorq Professional 7 Reagents

Working with Lamotte ColorQ Professional 7 reagents calls for cautious consideration to security protocols. Correct dealing with and disposal are essential to reduce dangers and guarantee a protected laboratory setting. Understanding the potential hazards and implementing applicable security measures protects each personnel and the encircling setting.Correct dealing with procedures, coupled with the proper private protecting gear (PPE), are basic to a protected and efficient analytical course of.
Following established disposal procedures for used reagents and options is important for environmental safety and compliance with laws. This part Artikels the essential security concerns for dealing with Lamotte ColorQ Professional 7 reagents.
Security Precautions
Dealing with chemical reagents requires adhering to strict security protocols. These precautions are important to forestall accidents and keep a protected working setting. Correct labeling and storage are essential to make sure that personnel can determine and deal with reagents accurately. Moreover, it’s essential to have clear and accessible security knowledge sheets (SDS) for all reagents.
Private Protecting Gear (PPE)
Utilizing applicable private protecting gear (PPE) is important to safeguard towards potential hazards. A complete PPE technique minimizes publicity to hazardous substances and reduces the danger of accidents.
- Security glasses or goggles are important to guard the eyes from splashes or fumes.
- Lab coats present safety for clothes and pores and skin towards chemical contact.
- Gloves, ideally chemical-resistant, are essential to forestall pores and skin contact with reagents.
- Closed-toe sneakers and pants are essential for stopping unintended chemical publicity to ft and legs.
Reagent Disposal Procedures
Correct disposal of used reagents and options is essential for environmental safety and compliance with laws. Improper disposal can result in contamination of water sources and pose dangers to human well being.
- Comply with particular directions supplied with every reagent for applicable disposal strategies.
- Used options needs to be disposed of in designated containers in response to native laws and waste administration pointers.
- By no means pour reagents down the drain except explicitly licensed by the disposal directions.
- All the time double-check the precise directions for disposal procedures supplied with the reagent or from the security knowledge sheet (SDS).
Potential Hazards and Dangers
Sure reagents may current particular hazards. Understanding these dangers helps in implementing applicable security measures.
- Some reagents could also be corrosive, inflicting pores and skin burns or harm to eyes upon contact.
- Others could be flammable, presenting hearth hazards if mishandled or uncovered to open flames.
- Sure reagents may launch dangerous fumes or vapors, necessitating enough air flow.
- Some reagents could also be poisonous, requiring particular dealing with and disposal procedures.
Security Information Sheets (SDS) Abstract
The next desk summarizes the important info discovered within the security knowledge sheets for widespread Lamotte ColorQ Professional 7 reagents. This desk supplies fast entry to essential info for every reagent.
Reagent | Potential Hazards | PPE Necessities | Disposal Directions |
---|---|---|---|
Reagent A | Corrosive, Flammable | Security glasses, lab coat, gloves | Designated chemical waste container |
Reagent B | Poisonous, Irritant | Security glasses, lab coat, gloves, respirator | Particular hazardous waste container |
Reagent C | Flammable, Oxidizing | Security glasses, lab coat, gloves, fire-resistant apron | Designated flammable waste container |